Shanghai Yang Ma Generator Co., Ltd.
Products
Contact Us
  • Contact Person : Ms. Chang Emma
  • Company Name : Shanghai Yang Ma Generator Co., Ltd.
  • Tel : 86-21-51375215
  • Fax : 86-21-51375215
  • Address : Shanghai,shanghai,No 1143 Pujian Road pudong new area District Shanghai China
  • Country/Region : China
  • Zip : 201024

50HZ 1500RPM 380V 50KW /62KVA electric power perkins Diesel generator set

50HZ 1500RPM 380V 50KW /62KVA electric power perkins Diesel generator set
Product Detailed
Related Categories:Diesel Generators
generator set 1)Perkins,65-70dB silent 2)8hrs fuel tank 100% load 100% cooper 3)electric start,ATS,AMF PERKINS generator seT

generator set

50HZ 1500RPM 380V 50KW /62KVA electric power perkins Diesel generator set

water cooled,8kw-1850kw,perkins diesel generator set with stamford ,marathon, leroy somer etc alternator equiped

open or silent type, single phase or three phase, 50 or 60hz, 1500 or 1800rpm

 1)Specifications 

Diesel Generatorperkins power plantStamford dynamo13 Year Gen-set manufacture experience4-Poles,1500RPM 50Hz 400V/230V 

diesel generator Voltage:400V/1500r/m

diesel generator Frequency:50Hz

diesel generator Power factor:0.8

diesel generator Phase:3Ph 4Wr

diesel generator Protection degree: IP23

diesel generator Insulation Class: H

diesel generator Efficiency more than: 85%

diesel Generator passed CE certificate

diesel Generator passed ISO certificate

 2)Detailed specification sheet: 

Perkins engine is a known world famous engine manufacturer, the product has a small size, light weight, stable performance , low fuel consumption, less emission characteristics, and its emissions is the domestic industry with the lowest engine emissions models.
 
 Power(KW)Current(A)Engine modelBrandPower(KW)CylinderBore(mm)Stroke(mm)fuel consumption  ≤g/kW.h
Genset Model
PS7GF712.6403D-11GPerkins7.2377818
PS10GF1018.1403D-15GPerkins10.4384908.9
PS15GF1527.1404D-22GPerkins16.24841009.6
PS20GF2036.2404D-22TGPerkins21.448410011
PS30GF3054.31103A-33TG1Perkins36310512711.6
PS40GF4072.41103A-33TG2Perkins48310512712
PS50GF5090.51104C-44TAG1Perkins64410512713
PS75GF75135.71104C-44TAG2Perkins80410512715
PS90GF90162.91006TGAPerkins109610512725
PS100GF100180.11006TAG2Perkins120610512728
PS120GF120217.21106C-E66TAG4Perkins147610512730
PS150GF150271.51306C-E87TAG3Perkins166610512745.2
PS200GF200360.21306C-E87TAG6Perkins200610512757.6
PS300GF3005432206A-E13TAG3Perkins320610512781.4
PS400GF4007242506A-E15TAG1Perkins4006105127109
PS500GF5009052806A-E18TAG2Perkins5206105127130
PS600GF60010864006-23TAG3APerkins6406160190140
PS700GF70012674008TAG2APerkins8188160190188
PS800GF80014484012-46TWG2APerkins100212160190290.3
PS904GF9041636.24012-46TWG3APerkins109112160190290.3
PS1000GF100018104012-46TAG2APerkins120412160190340
PS1200GF120021724016TAGPerkins140216160190380
PS1500GF150027154016TAG2APerkins164616160190430
PS1850GF185033484016TAG2APerkins188016160190490

3)Generator Warranty/Guarantee:1 year since on board or 1000 running hours subject to the earlier one. 

4)Functions 

1)LED control panel will Display loading power, voltages,currencies,frequency,speed,temperatures,oil pressure,running time etc.

2)Auto Warning when low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage,lower or over the water temperature etc.auto stop to protect the diesel gen-set

3)4 protection of :

Auto Shut down when over loading , low or high voltage, low or high frequency, over current, over or low speed, low or over battery voltage etc

Optional 

1. ATS: Automatic Transfer switch, which can start the diesel generator when the main power is off; when the main power comes back, it will shut down generator.

And ATS have the function of AMF (automatic Main power failure)

2. MCCB (molded case circuit breaker), which can protect the loading machine and the diesel generator.

3. Battery charger (float charger): when you haven’t used the gen-set for a long time, the batteries will be no power, in that way, you can’t start the generator. If you have battery charger, you can charge the batteries by the charger from main power.

4. Base fuel tank; daily fuel tank. We can change the capacity of fuel tank as per your demands

5. Paralleling system; This system can make several generators work together and automatically distribute the load according to set.

6. Remote Control Panel; we can control the 

gen-Set by computer, if we use a RS484 or RS232 digital cable to connect the gen-set to our computer.

7. Water separate; If the ambient temperature is too high, it will be harmful to our the diesel generator. Fan and water cooling is not enough for radiate. If we use water separate system, the life of generator will be much longer

8,Optional Diesel Gen-set Accessories

9.Warranty and Maintenance 

5)Products pictures:

6) Company strength and production line

7)Company Qualifications:

 8)Production capacity: 

1.  AIR COOLED DIESEL GENERATORS 

2.  WATER COOLED DIESEL GENERATORS 

3.  GASOLINE GENERATORS

 4.  DIESEL ENGINES

 5.  GASOLINE ENGINES 

6.  WATER PUMP& HIGH PRESSURE WASHER 

7.  WELDER GENRATORS 

8.  MOBILE LIGHT TOWER & TRAILER& CONTAINER GENERATOR 

9.  SPARE PARTS

50HZ 1500RPM 380V 50KW /62KVA electric power perkins Diesel generator set



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.